Air volume control valve is a common type of valve, which is widely used in various industrial and civil pipeline systems. In the clean room purification project, the air volume control valve is often used to adjust the branch pipe air volume of the fresh air system to achieve the mixed adjustment of fresh air and return air.
The air volume is controlled by adjusting the opening and closing angle of the valve blade. The valve adopts a closed structure, and the air leakage volume in the closed state does not exceed 2%. The manual valve adjustment mechanism is divided into a handle type and a worm gear type, and the air volume is adjusted by changing the opening and closing angle of the blades; the opening and closing angle of the blades of the electric valve is controlled by a motor. This air volume control valve has the characteristics of flexible operation, low noise, small leakage, wide working temperature range, reliable structure, safe and convenient use, etc., and is favored by major construction parties.
The air volume control valve is usually installed in the pipeline of the ventilation system or the air conditioning system. It can also be used to control the ventilation of the fire staircase to ensure that there is enough fresh air in the staircase in an emergency to prevent the spread of smoke and ensure the safety of personnel. Therefore, it is very common, and it is also one of the main references for the fire department to check the fire safety of the unit.
RELATED INFORMATION
Recently, Guangdong Global Purification Technology Co., Ltd. welcomed a group of important clients from Ukraine. These clients showed great interest in the company's expertise and products in the manufacturing field of non-standard pressure vessels, dryers, dust collectors, and other equipment, and specifically came to inspect and communicate.
2025-01-10
The qualification upgrade work has received great attention from the company's leadership and active participation from all employees.
2024-12-19
Diagnosis and troubleshooting of common faults of air compressor
The reasons for the failure of the unit are varied, a fault is usually not caused by a part or a factor, so the diagnosis and elimination of the fault is often difficult.
2024-10-31
National unified service hotline
Sales Phone:+868922631278(Mr. Wong)
E-mail:18922631278@163.com
Address: 6868 Zhuhai Avenue, Hongqi Town, Jinwan District, Zhuhai City
Sweep the attention to us
WeChat Public Number
Copyright©2024 Guangdong Global Purification Technology Co., Ltd. Website:www.300.cn SEO [ Privacy Policy ] DigitalCard